FSL-V-ZAB/SEK

SUPPLY AND EXTRACT AIR UNIT WITH HEAT EXCHANGER AND HEAT RECOVERY UNIT, SECONDARY AIR OPTION, FOR VERTICAL INSTALLATION ON AN EXTERNAL WALL, E.G. ADJACENT TO A WINDOW

Ready-to-operate decentralised ventilation unit that provides good comfort levels, used for the ventilation of rooms

  • Acoustically optimised EC fans with low specific fan powers, SFP-1 according to EN 13779
  • Recuperative plate heat exchanger (air/air), including bypass damper with electric actuator (open-close)
  • Heat exchanger for heating and cooling as 2-pipe or 4-pipe system
  • Unit base of approx. 0.13 m²
  • Reduction of fine dust and pollen contamination due to integral filters that conform to VDI 6022 – F7 fresh air filter and G3 extract air filter
  • Condensate drip tray with condensate drain
  • Motorised shut-off damper, normally closed (NC)
  • Automatic switching to secondary air mode (based on air quality)

Optional equipment and accessories

  • Modular control system FSL-CONTROL II, specially for decentralised ventilation systems
  • Demand-based fresh air volume, free cooling and night purge, depending on control strategy
  • Variable heat recovery
  • Powder-coated RAL 9005

SCHOOLAIR-V

SUPPLY AND EXTRACT AIR UNIT WITH HEAT EXCHANGER AND HEAT RECOVERY UNIT, SECONDARY AIR OPTION, FOR VERTICAL INSTALLATION ON AN EXTERNAL WALL, E.G. ADJACENT TO A WINDOW

Ready-to-operate decentralised ventilation unit that provides good comfort levels, used for the ventilation and extract ventilation of rooms such as classrooms in schools

  • Acoustically optimised EC fans with low specific fan powers, SFP-1 according to EN 13779
  • Recuperative plate heat exchanger (air/air), including bypass damper with electric actuator (open-close)
  • Alternatively: Rotary heat exchanger for heat recovery (air/air), including bypass with electric actuator (modulating or open-close)
  • Heat exchanger for heating and cooling as 2-pipe or 4-pipe system
  • Unit base of approx. 0.24 m²
  • Easy filter change, no tools required
  • Condensate drip tray with or without condensate drain
  • Motorised shut-off dampers, normally closed (NC)
  • Automatic switching to secondary air mode (based on air quality)

Optional equipment and accessories

  • Modular control system FSL-CONTROL II, specially for decentralised ventilation systems
  • Demand-based fresh air volume, free cooling and night purge, depending on control strategy
  • Variable heat recovery
  • Powder-coated RAL 9005 (black)

SCHOOLAIR-V-HV

SUPPLY AND EXTRACT AIR UNIT WITH SWITCHOVER OPTION TO SECONDARY AIR OPERATION, INCLUDING ROTARY HEAT RECOVERY UNIT AND HEAT EXCHANGER FOR VERTICAL INSTALLATION ON THE FACADE

Ready-to-operate decentralised ventilation unit that provides good comfort levels; used for the ventilation of internal spaces such as classrooms or conference rooms and day nurseries

  • Acoustically optimised EC fans with low specific fan powers, SFP-1 according to EN 13779
  • Rotary heat recovery unit (heat recovery efficiency 75 %) with moisture recovery in winter
  • Highly efficient heat exchanger for heating and cooling as 2-pipe or 4-pipe system
  • Heat exchanger connected on the right when seen from the room
  • Condensate drip tray with or without condensate drain
  • Year-round use of heat recovery
  • Reduction of fine dust and pollen contamination due to integral filters that conform to VDI 6022 – filter class ISO ePM1 65 % and extract air ISO coarse 50 %
  • Easy filter change, no tools required
  • Motorised shut-off dampers, normally closed (NC)
  • Installation without interruption to the operations of the respective school

Optional equipment and accessories

  • Modular control system FSL-CONTROL III, specially for decentralised ventilation units
  • Wood panelling as outer casing in various colours including TROX grilles for supply air and extract air (self-assembly kit)

SCHOOLAIR-V-HV-EH

SUPPLY AND EXTRACT AIR UNIT WITH THE OPTION OF SWITCHING TO SECONDARY AIR OPERATION, INCLUDING ROTARY HEAT RECOVERY UNIT AND ELECTRIC AIR HEATER FOR VERTICAL INSTALLATION ON THE FACADE

Ready-to-operate decentralised ventilation unit that provides good comfort levels; used for the ventilation of internal spaces such as classrooms or conference rooms and day nurseries

  • Acoustically optimised EC fans with low specific fan powers, SFP-1 according to EN 13779
  • Rotary heat recovery unit (heat recovery efficiency 75 %) with moisture recovery in winter
  • Electric air heater with maximum heating capacity of 1500 W
  • Condensate drip tray without condensate drain
  • Year-round use of heat recovery
  • Reduction of fine dust and pollen contamination due to integral filters that conform to VDI 6022 – filter class ISO ePM1 65 % and extract air ISO coarse 50 %
  • Easy filter change, no tools required
  • Motorised shut-off dampers, normally closed (NC)
  • Installation without interruption to the operations of the respective school

Optional equipment and accessories

  • Modular control system FSL-CONTROL III, specially for decentralised ventilation units
  • Wood panelling as outer casing in various colours including TROX grilles for supply air and extract air (self-assembly kit)

SCHOOLAIR-V-HE

SUPPLY AND EXTRACT AIR UNIT WITH SWITCHOVER OPTION TO SECONDARY AIR OPERATION, INCLUDING CROSS COUNTER FLOW HEAT RECOVERY UNIT AND HEAT EXCHANGER FOR VERTICAL INSTALLATION ON THE FACADE

Ready-to-operate decentralised ventilation unit that provides good comfort levels and is used for the ventilation of internal spaces such as classrooms or conference rooms and day nurseries

  • Acoustically optimised EC fans with low specific
  • fan power, SFP = 1 to EN 13779
  • Cross counter flow heat recovery unit (84% heat recovery efficiency)
  • Highly efficient heat exchanger for heating and cooling as 2-pipe or 4-pipe system
  • Heat exchanger connection is on the right when seen from the room
  • Condensate drip tray with drain (drainage by others)
  • Heat recovery all year round
  • Reduced fine dust and pollen contamination due to integral filters that conform to VDI 6022 – filter class ISO ePM1 65% and extract air ISO coarse 55%
  • Easy filter change, no tools required
  • Motorised shut-off dampers, normally closed (NC)
  • Installation without interruption to the operations of the respective school

Optional equipment and accessories

  • Modular control system FSL-CONTROL III, specially for decentralised ventilation systems
  • Wood panelling as a room solution in diverse colours including TROX grilles for supply air and extract air (assembly kit)

SCHOOLAIR-V-2L

SUPPLY AND EXTRACT AIR UNIT WITH SWITCHOVER OPTION TO SECONDARY AIR OPERATION, INCLUDING CROSS FLOW HEAT RECOVERY UNIT AND HEAT EXCHANGER FOR VERTICAL INSTALLATION ON THE FACADE

Ready-to-operate decentralised ventilation unit that provides good comfort levels and is used for the ventilation of internal spaces such as classrooms or conference rooms and day nurseries

  • Acoustically optimised EC fans with low specific fan powers, SFP-1 according to EN 13779
  • Cross flow heat recovery unit (heat recovery efficiency 52 %) 
  • Highly efficient heat exchanger for heating as 2-pipe system
  • Heat exchanger connection on the right when seen from the room
  • Condensate drip tray with or without condensate drain
  • Year-round use of heat recovery is optional
  • Reduction of fine dust and pollen contamination due to integral filters that conform to VDI 6022 – filter class ISO ePM1 65 % and extract air ISO coarse 50 %
  • Easy filter change, no tools required
  • Motorised shut-off dampers, normally closed (NC)
  • Installation without interruption to the operations of the respective school

 

Optional equipment and accessories

  • Modular control system FSL-CONTROL III, specially for decentralised ventilation units
  • Wood panelling as outer casing in various colours including TROX grilles for supply air and extract air (self-assembly kit)

SCHOOLAIR-V-4L

SUPPLY AND EXTRACT AIR UNIT WITH SWITCHOVER OPTION TO SECONDARY AIR OPERATION, INCLUDING CROSS FLOW HEAT RECOVERY UNIT AND HEAT EXCHANGER FOR VERTICAL INSTALLATION ON THE FACADE

Ready-to-operate decentralised ventilation unit that provides good comfort levels and is used for the ventilation of internal spaces such as classrooms or conference rooms and day nurseries

  • Acoustically optimised EC fans with low specific fan powers, SFP-1 according to EN 13779
  • Cross flow heat recovery unit (heat recovery efficiency 52 %)
  • Highly efficient heat exchanger for heating and cooling as 4-pipe system
  • Heat exchanger connection on the right when seen from the room
  • Condensate drip tray with or without condensate drain
  • Year-round use of heat recovery is possible
  • Reduction of fine dust and pollen contamination due to integral filters that conform to VDI 6022 – filter class ISO ePM1 65 % and extract air ISO coarse 50 %
  • Easy filter change, no tools required
  • Motorised shut-off dampers, normally closed (NC)
  • Installation without interruption to the operations of the respective school

Optional equipment and accessories

  • Modular control system FSL-CONTROL III, specially for decentralised ventilation units
  • Wood panelling as outer casing in various colours including TROX grilles for supply air and extract air (self-assembly kit)

SCHOOLAIR-V-1800

SUPPLY AND EXTRACT AIR UNIT WITH SWITCHOVER OPTION TO SECONDARY AIR OPERATION, INCLUDING CROSS FLOW HEAT RECOVERY UNIT AND HEAT EXCHANGER FOR VERTICAL INSTALLATION ON THE FAÇADE

Ready-to-operate decentralised ventilation unit that provides good comfort levels and is used for the ventilation of internal spaces such as classrooms, conference rooms and day nurseries

  • Acoustically optimised EC fans with low specific fan power, SFP = 1 to EN 13779
  • Cross flow heat recovery unit (heat recovery efficiency 57 %)
  • Construction height of only 1800 mm
  • Highly efficient heat exchanger as 2-pipe or 4-pipe system
  • Heat exchanger connection is on the right when seen from the room
  • Condensate drip tray with or without condensate drain
  • Heat recovery all year round (optional)
  • Reduced fine dust and pollen contamination due to integral filters that conform to VDI 6022 – filter class ISO ePM1 65% and extract air ISO coarse 50%
  • Easy filter change, no tools required
  • Motorised shut-off dampers, normally closed (NC)
  • Installation without interruption to the operations of the respective school

Optional equipment and accessories

  • Modular control system FSL-CONTROL III, specially for decentralised ventilation systems
  • Wood panelling as outer casing in various colours, with TROX ventilation grilles for supply air and extract air (assembly kit)