Filter inserts

AKR

CIRCULAR PLENUM BOX FOR UNIVERSAL CONNECTION OF SWIRL DIFFUSERS TYPE VDW, FD, TDF, AIRNAMIC AND XARTO

Standard plenum box for supply air and extract air for circular diffuser faces and for the XARTO type 

  • Plenum box made of galvanised sheet steel with plastic spigot and equalising element made of polyester fleece
  • Mounting aid for faster and tool-free assembly of the diffuser face
  • 3 suspension lugs for fixing, alternatively a central single-point suspension can be used 
  • For all types of ceiling systems
  • Equalising element for optimum and therefore quieter flow through the diffuser face with supply air
  • For comfort zones and industrial zones
  • Very airtight casing

 

Optional equipment and accessories

  • Spigot with damper unit for volume flow rate balancing and lip seal
  • Internal lining
  • Powder coating, RAL CLASSIC colour

Filter elements

MFE

VERY COMPACT, FOR MODULAR INSTALLATION

Pre-filters or final filters for the separation of fine dust and particulate filters for the most critical requirements in ventilation systems

 

  • Filter groups ISO ePM1 (fine dust filter) and EPA, HEPA (particulate filter)
  • Performance data tested according to ISO 16890 or  to EN 1822-1 and ISO 29463-2 to ISO 29463-5
  • Eurovent certification for fine dust filters
  • Filter media for special requirements, made of glass fibre papers, with spacers made of textile threads
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Meets the hygiene requirements of VDI 6022

Filter Cells

MFC

FOR LARGE VOLUME FLOW RATES AND LONG FILTER LIFE

Prefilters or final filters for the separation of fine dust and particulate filters for the most critical requirements in ventilation systems

  • Filter groups ISO ePM10, ISO ePM1 (fine dust filter) and EPA, HEPA (particulate filter)
  • Performance data tested in accordance with ISO 16890 or with EN 1822-1 and ISO 29463-2 to ISO 29463-5
  • Eurovent certification for fine dust filters
  • Filter media for special requirements, glass fibre papers with spacers made of thermoplastic hot-melt adhesive
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Compact V-design with low installation depths
  • Fitting into ducted particulate filters (types KSF, KSFS) and duct casings for particulate filters (type DCA)
  • Meets the hygiene requirements of VDI 6022

Panel Filter

MFP

FOR THE MOST DEMANDING REQUIREMENTS OF AIR CLEANLINESS AND STERILITY

Prefilters or final filters for the separation of fine dust and suspended particles. Used for industrial, research, medical, pharmaceutical, and nuclear engineering applications.

  • Filter groups ISO ePM10, ISO ePM1 (fine dust filter) and EPA, HEPA (particulate filter)
  • Performance data tested according to ISO 16890 or  to EN 1822-1 and ISO 29463-2 to ISO 29463-5
  • Eurovent certification for fine dust filters
  • Meets the hygiene requirements of VDI 6022
  • Filter media for special requirements, glass fibre papers with spacers made of thermoplastic hot-melt adhesive
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Perfect adjustment to individual requirements due to different pleat depths, filter frame made of various materials
  • Fitting into ceiling mounted or wall mounted particulate filters (types TFC, TFW, TFM, TFP), ducted particulate filters (types KSF, KSFS), duct casings for particulate filters (type DCA), or operating theatre ceilings
  • Automatic filter scan test for all filters from filter class H14

Filter cartridges

MFCA

COMPACT CONSTRUCTION FOR SPECIAL APPLICATIONS

Final filters for the separation of suspended particles to meet the highest requirements

  • Filter classes E11, H13
  • Performance tested in accordance with EN 1822-1 and ISO 29463-2 to ISO 29463-5
  • Filter media for special requirements, glass fibre papers with spacers made of thermoplastic hot-melt adhesive
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Meets the hygiene requirements of VDI 6022

Filter panels for clean room technology

MFPCR

FOR THE MOST DEMANDING REQUIREMENTS ON THE PURITY OF INDOOR AIR, WORKSTATIONS, AND DEVICES

HEPA and ULPA filters as high-efficiency particulate filters for the separation of suspended particles in clean room systems. Used for industrial, research, medical, pharmaceutical, and nuclear engineering applications.

  • Filter classes H14, U15, U16
  • Performance tested in accordance with EN 1822-1 and ISO 29463-2 to ISO 29463-5
  • Meets the hygiene requirements of VDI 6022
  • Filter media for special requirements, glass fibre papers with spacers made of thermoplastic hot-melt adhesive
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Perfect adjustment to individual requirements due to variable pleat depths
  • Fitting into filter fan units, clean room workbenches, or operating theatre ceilings
  • Automatic filter scan test

Filter panels with hood

FHD

FOR THE MOST CRITICAL REQUIREMENTS IN CLEAN ROOM AREAS

Final filters for the separation of suspended particles, suitable for industrial, research, medical, and pharmaceutical applications

  • Filter classes E11, H13, H14, U15
  • Performance factory tested to EN 1822-1 and ISO 29463-2 to ISO 29463-5
  • Filter media for special requirements, glass fibre papers with spacers made of thermoplastic hot-melt adhesive
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Perfect adjustment to individual requirements due to different constructions
  • Filter hood available in various sizes and the usual grid sizes
  • Automatic filter scan test for all filters from filter class H14
  • Meets the hygiene requirements of VDI 6022

Optional equipment and accessories

  • Mechanism for volume flow rate setting