Zone Module

X-AIR-ZMO

ZONE MODULES FOR SINGLE ROOM CONTROL

X-AIRCONTROL zone modules for single room control, with interfaces to a control panel and to a zone master module

  • Single room control system for the demand-based control of temperature, air quality and humidity, and for detecting room occupancy
  • Connection of a room temperature sensor, motion detector, VOC or CO2 sensor as well as of a window contact, frost protection sensor or dew point sensor
  • Connection of air terminal units for supply air and extract air
  • Connection of a heating valve and a cooling valve
  • Connection of a room control panel
  • Single room control system can be expanded by centralised functions if a zone master is used

Optional equipment and accessories

  • VAV terminal units for supply and extract air
  • Valves with actuator for heating and cooling
  • Control panels with setpoint value adjuster or touch screen
  • Sensors

X-AIR-ZMO-MOD

ZONE MODULE MODBUS RTU FOR SINGLE ROOM CONTROL SYSTEM

X-AIRCONTROL zone module Modbus RTU for single room control, with interfaces to a room control panel and zone master module

  • Control of TROX air terminal units with Modbus RTU interface for supply and extract air
  • Control of a heating valve and a cooling valve with a Modbus RTU interface (TROX approval required)
  • Single room control system for the demand-based control of temperature, air quality and humidity, as well as the detection of room occupancy
  • Connection of a room temperature sensor, motion detector, VOC or CO2 sensor as well as of a window contact, frost protection sensor or dew point sensor
  • Connection of a room control panel
  • Single room control system can be expanded by centralised functions if a zone master is used

 

Optional equipment and accessories

  • TROX air terminal units with Modbus RTU interface for supply and extract air.
  • Valve actuators with Modbus RTU interface for heating and cooling (TROX approval required)

X-AIR-ZMO-MP

ZONE MODULE MP BUS FOR SINGLE ROOM CONTROL

X-AIRCONTROL zone module MP bus for single room control, with interfaces to a room control panel and zone master module

  • Control of TROX air terminal units with MP bus interface for supply and extract air.
  • Control of a heating valve and a cooling valve with MP bus interface
  • Single room control system for the demand-based control of temperature, air quality and humidity, as well as the detection of room occupancy
  • Connection of a room temperature sensor, motion detector, VOC or CO2sensor, as well as of a window contact, frost protection sensor or dew point sensor
  • Connection of a room control panel
  • Single room control system can be expanded by centralised functions if a zone master is used

 

Optional equipment and accessories

  • VAV terminal units with MP bus interface for supply and extract air
  • Valve actuators with MP bus interface for heating and cooling
  • Control panels with setpoint value adjuster or touchscreen
  • Sensor systems

X-AIR-ZMO-EXT

MODULE FOR ZONE EXPANSION

  • Module for zone expansion of the control system X-AIRCONTROL to connect additional cooling and/or heating valves or electric air heaters to a zone module
  • Control input signal of maximum 4 cooling or 4 heating valve actuators per analogue output
  • Control input signal of maximum 2 electric air heaters
  • Control input signal of cooling and heating valve actuators and electric air heaters via 2 analogue outputs (0 – 10 V DC)
  • 2 temperature sensor inputs (PT1000) are available for temperature monitoring in the duct for electric air heaters

 

Useful additions

  • X-SENS-TEMP-PT1000 duct temperature sensor PT1000