Splitter Sound Attenuators

MS

SPLITTER SOUND ATTENUATOR WITH HIGH INSERTION LOSS, EVEN IN THE LOW-FREQUENCY RANGE

Splitter sound attenuator, basically a duct section with integral splitters (type MK) with resonating panels, for ventilation and air conditioning systems

  • Attenuation effect due to absorption and resonance
  • Energy efficient due to aerodynamically formed frame (bullnose radius 20 mm)
  • Sound absorbing material is biosoluble and hence hygienically safe
  • Sound absorbing material faced with glass fibre fabric as a protection against erosion due to airflow velocities up to 20 m/s
  • The sound absorbing material is non-combustible, to EN 13501, fire rating class A1
  • Leakage class C and pressure class 2 according to EN 15727
  • For use in areas with potentially explosive atmospheres (according to EC Directive 2014/34/EU (ATEX)), zones 1, 2, and zones 21 and 22 (outside) according to EC Directive 1999/92/EC
  • Operating temperature up to 100 °C, with expanded metal (variant L) up to 300 °C for a limited period of time

Optional equipment and accessories

  • Expanded metal as an additional mechanical protection for the sound absorbing material
  • Stainless steel variant A2 (1.4301), with optional perforated metal facing as an additional protection for the sound absorbing material
  • Other stainless steel and aluminium variants as well as PUR coating are upon request

XS

SPLITTER SOUND ATTENUATOR WITH HIGH INSERTION LOSS, EVEN IN THE HIGH-FREQUENCY RANGE

Splitter sound attenuator, basically a duct section with integral splitters (type XK), for ventilation and air conditioning systems

  • Attenuation effect due to absorption
  • Energy efficient due to aerodynamically formed frame (bullnose radius 20 mm)
  • Sound absorbing material is biosoluble and hence hygienically safe
  • Sound absorbing material faced with glass fibre fabric as a protection against erosion due to airflow velocities up to 20 m/s
  • The sound absorbing material is non-combustible, to EN 13501, fire rating class A1
  • Leakage class C and pressure class 2 according to EN 15727
  • For use in areas with potentially explosive atmospheres (according to EC Directive 2014/34/EU (ATEX)), zones 1, 2, and zones 21 and 22 (outside) according to EC Directive 1999/92/EC
  • Operating temperature up to 100 °C, with expanded metal (variant L) up to 300 °C for a limited period of time

Optional equipment and accessories

  • Expanded metal as an additional mechanical protection for the sound absorbing material
  • Stainless steel variant A2 (1.4301), with optional perforated metal facing as an additional protection for the sound absorbing material
  • Other stainless steel and aluminium variants as well as PUR coating upon request